Coleman Heating and Conditioning
The indoor outfitters
Distributor Locator
HC5B
HC5B
Nominal Capacities
024 - 060

Efficiency
Up To 15 SEER

Warranty
Compressor - 10-Year Limited*
Parts - 10-Year Limited*
EnergyStart
Echelon 15 SEER Split System Heat Pump
The HC5B Series unit is the outdoor part of a versatile heat pump system.  It is designed to be custom matched with one of our complete line of evaporator sections, each designed to serve a specific function.  Matching air handlers are available for upflow, downflow and horizontal left or right applications to provide a complete system.  Electric heaters are available if required.  Add-on coils are available for use with upflow, downflow or horizontal furnaces.  Field installed accessories are available as needed.
Special Benefits
  • Superior Coil Protection - A PVC coated steel coil guard completely protects coil from debris and other large damaging material while a polymer mesh further protects the coil against smaller particles.
  • Isolated Compressor Compartment - A molded composite bulkhead isolates the compressor from the rest of the unit reducing sound and vibration.
  • Protected Compressors - Each compressor is protected against high and low pressure as well as excessive temperature.  This is accomplished by the simultaneous operation of high pressure relief valve and temperature sensors which protect the compressor if undesirable conditions occur.  A factory installed liquid line filter drier further protects the compressor.
  • Environmental Friendly Refrigerant - Next generation refrigerant R0410a delivers environmentally friendly performance with zero ozone depletion.
  • Durable Finish - Automotive quality finish provides the ultimate protection from harmful U.V. rays applied over a baked-on primer, using a Galvanized, zinc coated steel base material.  The result is a finish that has been proved in testing to provide 33% greater durability than conventional powder-coat finishes.
  • Lower Installed Cost - Designed to provide enhanced installability by featuring a slide-down control compartment allowing easy access to control components along with angled service valves to reduce overall installation time and cost.
  • Low Operating Sound Levels - A fan design boasting technology adapted from aeronautic and defense engineering provides for whisper quiet operation by allowing airflow to flow smoothly and efficiently across the fan tips.
  • Filter-Drier - A factory installed, solid core liquid line filter-drier filters harmful debris and moisture from the system.
  • Easy Service Access - A full end, full service, access panel with handle makes for easy entry to internal components.
  • Long Lasting Operation - Strong and durable composite base pan provides added strength while resisting rust and corrosion as well as reducing sound and vibration.
  • Whisper Drive System - Features combination of swept-wing fan, composite base pan, isolated compressor compartment and two-stage compressor to reduce overall sound to a mere whisper.
  • Complete System Control - These heat pumps utilize the unique microprocessor defrost control system to provide optimal comfort as well as monitor the overall system for reliable operation.  In the event improper operating conditions occur (high temperature and/or high pressure), the system will automatically shut the system down to extend the life of the heat pump.  The defrost control features an internal memory to aid the technician in troubleshooting, reducing service time and cost.

*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate. This warranty does not apply to R-22 or 3-phase models.

Publications and Manuals
DescriptionPart NumberFile Size
Tech Guides
Technical Guide - HC5B024 thru 060*C, Echelon Split System Heat Pump (15 SEER)556750-CTG-B-1210442.0 KB PDF
Technical Guide - HC5B024* thru 060*C Echelon R-410A Split System Heat Pumps (15 SEER)505539-CTG-A-0909418.0 KB PDF
Tabular Data
Tabular Data Sheet - HC5B024* thru 060*(C) R-410A Outdoor Split System Heat Pump (15 SEER)536645-CTD-A-1009211.0 KB PDF
Accessory Installation Instructions
Installation Accessory - 2SA067* Hard Start Kit for 13+ SEER Air Conditioners and Heat Pumps364024-UAI-D-1011514.0 KB PDF
Submittal Drawings
Submittal Data Sheet - HC5B024 thru 060 Echelon Split System Heat Pump (15 SEER)563733-CSD-A-0410247.0 KB PDF
Repair Parts
Repair Parts - HC5 Series R-410A Heat Pump – Outdoor Unit, Style C & D (15 SEER)035-22207-001-E-0711519.0 KB PDF
Repair Parts - HC5 Series R-410A Split System Heat Pumps with Communicating Controls, 3rd Generation "Style A" (15 SEER)035-22761-001-C-0410840.0 KB PDF
Repair Parts - HC5B Series Echelon™ R-410A Split-System Heat Pump "Style A, B, & C" (15 SEER)035-20635-001-M-0711515.0 KB PDF
User Manuals
User Manual - CZE, YZE, AC5B, HC5B, AL5B, & HL5B Series R-410A Split System Air Conditioners or Heat Pumps (15 SEER)361821-UUM-B-0409151.0 KB PDF